Symptom
- DirectConnect(DC) server is not starting.
- DC server log shows:
LogOCOSMessages 06/19/2020 16:20:03.270760 xxxxx NULL NULL NULL Error: 16240 Severity: 10 State: 0 OS Error: 67 : Net-Library routine sybnet_listen() failed in srv__start_net Network error: status = 23 - Net-Lib protocol driver call to register a listener failed OS Error Text: Socket bind failed - errno 67 Address already in use <SRV-Lib>
LogOCOSMessages 06/19/2020 16:20:03.270939 xxxxxx NULL NULL NULL Error: 16029 Severity: 20 State: 0 OS Error: -1 : Failed to start any network listeners OS Error Text: <SRV-Lib>
Read more...
Environment
- DirectConnect 15.0 ESD#6 P-EBF19095-19101
- IBM RS/6000 AIX v4.3.x
Product
SAP Sybase Mainframe Connect 15.0 ; Sybase EnterpriseConnect Data Access 15.7
Keywords
KBA , BC-SYB-MFC , Mainframe Connect (MFC) , BC-SYB-ECD , Enterprise Connect (ECDA) , Problem