SAP Knowledge Base Article - Preview

2944725 - Infected wtih Signal 11 in bt__logandinsdel() during CREATE INDEX WITH ONLINE - SAP ASE

Symptom

  • The command, CREATE INDEX command with WITH ONLINE option, on a data row locked or data only locked table fails with an "infected with signal 11"  error in function bt__logandinsdel() 

Current process (0xxxxxxxxx) infected with signal 11 (SIGSEGV)
Address 0x0x0000000001c6a909 (bt__logandinsdel+0x939), siginfo (code, address) = (1, 0x0x0000000000000048)

  • The error is accompanied by a stack trace referencing the functions:

kisignal
bt__logandinsdel
bt__delete
bt_delete
onlutl__perform_ncdelete
onlutl__apply_insdel_lr
onlutl_logical_sync
cri_bldindex
cri_main


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16.0 for Business Suite
  • SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 16.0

Keywords

821225, CR821225, CR#821225, shutdown, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers , KBA , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed