Symptom
When Quick Create screen is opened, the Custom Quick Create is overwriting the Standard Quick Create.
Environment
- SAP Cloud Application Studio
- SAP Cloud for Customer
- SAP Business byDesign
Reproducing the Issue
Pre-requisite: You have created and configured a Custom Quick Create (QC) and added it to a standard screen via the Cloud Application Studio.
- Open the Standard Workcenter view
- Open the OWL
- Click "+" to open the QC
- Custom QC is opened instead of the expected Standard QC
Cause
You are trying to reuse the standard QC's configuration in your custom QC. In other words, the configured import of the ThingType for the Quick Create is the exact same for both QC's (standard and custom).
During run-time, the PDI QC is overwriting the standard QC, which triggers the PDI QC import and displays the custom screen instead of the standard.
Resolution
You need to remove the custom QC and/or configure it in a different way, so that the standard QC will be available once more during run-time.
Keywords
Quick create, QC, PDI, overwrite, thing type, import , KBA , AP-RC-BDS-UI , ByDesign Studio UI Generation , Problem