Symptom
- "Infected with signal 11" error in the module LeScanOp::_LeOpClose() together with a stack trace is reported in the ASE errorlog:
Current process (0x5eef04b3) infected with signal 11 (SIGSEGV)
Address 0x0x000000000188fcb9 (LeScanOp::_LeOpClose(ExeCtxt&)+0x49), siginfo (code, address) = (128, 0x(nil))
- The stack may include the following modules:
LeScanOp::_LeOpClose
LeOperator::LeOpClose
LeNLJOp::_LeOpNext
LeDeleteOp::_LeOpNext
LeEmitNoSndOp::_LeOpNext
LePlanNext
exec_lava
Note: A complete stack trace is available under Attachments.
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 16.0
Product
Keywords
SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, CR#821695, CR821695, 821695 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed