SAP Knowledge Base Article - Public

3033951 - Not Possible to Upload Notes to Installation Point via Data Workbench

Symptom

You want to update or insert notes for installation points via Data Workbench. The attempt fails with one or more of the following error types:

  • "The text type ABC does not belong to configuration profile XYZ" 
  • "Text type ABC does not exist"

(where ABC represents the type code and XYZ represents the configuration profile)

Note: Similar issues may appear for web services respectively registered products.

Environment

SAP Cloud for Customer

Cause

For installation points, only 2 text types are allowed: 10011 and 10024. You are using another text type.

Resolution

  • When trying to create data in Installation Point via Data Workbench, adapt the upload file accordingly.
  • When using web services, please change the local code in code list mapping to 10011 or 10024.

Keywords

registered product, change, not possible, not working, for, impossible, unable, not able, note, create data, upsert, import , KBA , LOD-LE-IBA , Installed Base Data Management , Problem

Product

SAP Cloud for Customer add-ins all versions ; SAP Cloud for Customer core applications 2102