Symptom
- Error 'Entry for customizing subobject V_TEWMSERIAL not maintained in webgui maintenace' when trying to edit the Profile Text for the Serial Number Profile in SSCUI 102231.
Environment
- SAP S/4HANA Cloud
Reproducing the Issue
- Manage Your Solution.
- SSCUI 102231 Determine Serial Number Profiles.
- Edit Serial Profile.
- Error 'Entry for customizing subobject V_TEWMSERIAL not maintained in webgui maintenace'
Cause
The SSCUI 102231 should only be used to maintain serial number profiles without "warehouse serialization settings" and therefore the maintenance of this subview (and the copy function of the values, too) are locked.
Resolution
The maintenance of the "warehouse serialization settings" for harmonized serial number profiles was moved to the SSCUI '103636 Define Serial Number Profiles'.
Here you can maintain/create or copy your serial number profiles.
Keywords
KBA , MM-IM-GF , Basic Functions , MM-IM-GF-2CL , Basic Functions (Public Cloud) , SCM-EWM-CNT , S/4HANA Best Practices for EWM , Problem
Product
SAP S/4HANA Cloud 2108