Symptom
Popup window with "No entry for plant & and inspection type & in table TQSS1_AVE" appears when using the app Record Usage Decision
"Image/data in this KBA is from SAP internal systems, sample data, or demo systems. Any resemblance to real data is purely coincidental"
Environment
- SAP S/4HANA Cloud Public Edition
- Quality Management
Reproducing the Issue
- Access the app Record Usage Decision
- Input Inspection lot with Inspection Lot Origin 17
- Press Enter
- Press Button "WM Inspection"
- Popup window "Stock based Q-Inspection without Work Center" appears
- Press Pencil button "Action Q.Stock item"
- Press F4 on field Decision Code
- Popup appears
Cause
The SSCUI / Configuration Activity Maintain Settings at Plant Level is correctly maintained for the plant and inspection type involved but the entry for the field PL SEl.Set ( Selected Set for Usage Decision (Partial Lots) ) is missing
Resolution
Please maintain an entry for the field PL SEl.Set ( Selected Set for Usage Decision (Partial Lots) ) in the SSCUI / Configuration Activity Maintain Settings at Plant Level
See Also
Keywords