SAP Knowledge Base Article - Public

3154692 - Hierarchy is activating again after re-executing the variable screen in AO

Symptom

The hierarchy is activating again after re-executing the variable screen in AO.
In RSRT transaction, the hierarchy remains deactivated as expected.

Because of this issue, the following errors/warnings might be displayed:

No applicable data found
Characteristic <X> has no master data for <Y> or you do not have authorizations (com.sap.ip.bi.bics.dataaccess.consumer.impl.selector.selection.SingleMember-NoMasterdata)

Environment

SAP Analysis for Microsoft Office

Reproducing the Issue

1. Run query in AO or refresh an existing workbook;
2. Confirm hierarchy is activated;
3. Change hierarchy to flat presentation;
4. Open variable screen and re-execute (even with same values);
5. Confirm the hierarchy will activate again.

Resolution

Check and if applicable, implement the SAP Notes 314962931070663009842 and 2944239 in the BW system.