SAP Knowledge Base Article - Preview

3159472 - "Could not start (Adapter: 'ODataAdapter')" error occurs while executing OData task - SAP Cloud Integration for Data Services

Symptom

  • The following error occurs in the error log of CI-DS task that is reading or loading OData service table:

    Error preparing to load <<OData service table>>: <Could not start (Adapter: 'ODataAdapter').>

  • The server_eventlog (Windows: %DS_COMMON_DIR%\log\JobServer_DSoD_Agent; Linux: $LINK_DIR/log/JobServer_DSoD_Agent) contains the error below:

    JobServer: Error while instantiating the message broker or the adapter manager. TCP Protocol: Other application (or other instance of this application) is already using the port inet:<IP address>:4001. Ensure only one application uses the port at a time (BODI-42) (BODI-850041)


Read more...

Environment

SAP Cloud Integration for Data Services 1.0.11.xxxx

Product

SAP Cloud Integration for data services all versions

Keywords

LOD-HCI-DS, CPI-DS, CI-DS, HCI, OData, configuration, 4001, port , KBA , LOD-HCI-DS , HANA Cloud Integration for Data Services , Problem