Symptom
- "Create Measurement Document" & "Change Measurement Documents" apps display posting time by default in UTC .
- The field MeasTime ( Measurement Time ) is not showing the time in the users local time.
- Popup with 'Measurement time cannot be in the future' when adjusting the field MeasTime ( Measurement Time ) to the local time of a user in the app "Create Measurement Document".
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Access the app Create Measurement Document ( App ID IK11 ) or Change Measurement Documents ( App ID IK18 ).
- Change the field MeasTime ( Measurement Time ) to the local time of the user.
Cause
Create Measurement Document(IK11) and Change Measurement Documents(IK18) are GUI for HTML apps. GUI for HTML apps always take the system timezone and do not read the Fiori Launchpad timezone even though they run within the FLP.
Resolution
Use WDA application "Create Measurement Document for Technical Object" to create new measurement document instead of using GUI for HTML apps.
Or follow the KBA 2963059 - How to Submit Feature Requests for SAP S/4HANA Cloud Product and submit a feature request if you would like the functionality added to GUI for HTML apps in a future Release.
See Also
Keywords
RIMR0-DFTIM, Create Measurement Document, IK11, IK18, UTC, Time zone, MeasTime, GUI for HTML, WDA. , KBA , PM-EQM-SF-MPC-2CL , Measuring points and counters (Public Cloud) , PM-FIO , Fiori User Interface (UI) for PM , PM-EQM-SF-MPC , Measuring points and counters , Problem