Symptom
I receive 'Table_Schema_Failed...Socket Error' in the Process Intelligence 'Integration Page' when trying to add a table.
Environment
SAP Signavio Process Intelligence 3.0
Reproducing the Issue
- Open new investigation in Process Intelligence.
- Navigate to the Integration page.
- Click on add table.
- Next, select the table name.
- Click next.
- See that you are faced with a 'socket closed' error.
Cause
The Process Intelligence application fails to get tables and columns due to a slow response, which causes a SocketTimeoutException after 30 seconds by default
Resolution
- Add the parameter "timeout = 600" to the "Extra Connection Arguments" in the "Connection" page.
- Then try to add the table once again.
Keywords
process, intelligence, socket, error, table, schema, failed, integration, page, add , KBA , BPI-SIG-PI-DS , Data Source (CSV, Connector) , Known Error
Product