3259366 - Full database backup crashed IQ server with signal 11 after upgrade to 16.1 SP04PL09 -- SAP IQ

Symptom

  • Aftre upgrade IQ server to 16.1 SP04 PL09, runnign a full databse backup cause IQ server to crash without any stracktrace in iqmsg file. 
  • The backup failed near the end of the backup.
  • In the .stderr file, the following error reported:

**************************************************
*** SAP IQ Abort:
*** From: stcxtlib/st_server.cxx:2455
*** PID: 81334
*** Message: caught signal 11, program abort
*** Thread: 140737354024768 (TID: 1)
**************************************************

140737354024768 Stacktrace requested from stcxtlib/st_server.cxx:2455 on thread 140737354024768 (TID 1) start stacktrace
********************************
[hos_InMemMsgLog::Dump()] BEGIN*
Time: 1662850493133111
[hos_InMemMsgLog::Dump()] END***
********************************

While handling one abort, encountered another abort from the same thread.
Calling emergency shutdown.
While handling one abort, encountered another abort from the same thread.
Calling emergency shutdown.

  • Re-run the same full backup and it may run successfully. 