Symptom
- On SAP Business Suite or SAP BW systems on SAP ASE database, DBA Cockpit -> Data Collector Framework -> Tables collector fails with error 14108 or a signal 11
- ASE log reports error 14108 with a stack trace including ptn__get_pdes
Error: 14108, Severity: 20, State: 4
Could not find partition descriptor for objid %d, indid -%d, ptnid %d in dbid %d.
or
- A signal 11 at address ptn__get_pdes
Current process (0x297f0431) infected with signal 11 (SIGSEGV)
Address 0x0x00000000019c13e0 (ptn__get_pdes+0x30) ... - Both are followed by a stack trace including modules
ptn_get_pdes
ptn_pdes_set
open_partition
get_datachange
LeRun
Read more...
Environment
- SAP Adaptive Server Enterprise (ASE) 16.0 SP03 for Business Suite
- SAP Netweaver / ERP
Keywords
14108, signal, stack trace, 827473, ptn_get_pdes , KBA , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Problem