Symptom
The system has an ASCS instance running with the Standalone Enqueue Server 2 (ENSAv2) in a HA (High Availability) / cluster environment.
The system also has an ERS instance running the Enqueue Replicator 2 (ER2).
Even so, the locks are lost if there is a failover of the ASCS.
At the transaction SMENQ -> Server Administration, the "Replication" state has yellow background with text "Active (update pending)".
The following (or similar) entries are seen at the ENSAv2 trace file (dev_enq_server):
[date and time] [Thr nnn] EnqReplica: replication enabled
[date and time] [Thr nnn] EnqReplManager: connecting ER2 on hostname:sapdpXX
[date and time] [Thr nnn] EnqReplManager: starting master thread
[date and time] [Thr nnn] ***LOG GOD=> SystemLog, ReplicaSuspended () [EnqSystemLog 86]
[date and time] [Thr nnn] EnqReplManager: repairing replication
[date and time] [Thr nnn] EnqReplManager: master channel NOT connected (8.1 seconds)
Read more...
Environment
- SAP NetWeaver based product
- ABAP Platform based product
- Standalone Enqueue Server 2
Product
Keywords
KBA , BC-CST-EQ , Enqueue , BC-CST , Client/Server Technology , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.