SAP Knowledge Base Article - Preview

3291933 - Spid <> has exceeded its timeout value while issuing a write for virtual device 0 - ASE

Symptom

  • The following error was reported in the ASE error log:

Spid 449 has exceeded its timeout value while issuing a write for virtual device 0

  • The server error log later reported:

(<path to master.dat>). A system call has not responded for 50 seconds, and Adaptive Server will be impacted until it returns. Contact your operating system vendor for assistance.

  • users are not able to log into ASE
  • Need to issue a kill -9 to shutdown server
  • Server reboot reported the following error in the ASE error log:

basis_dlock: file "<path to master.dat>" already in use by an ASE
kdconfig: unable to read primary master device
kiconfig: read of config block failed

  • When running OS command /sbin/fuser <path to master.dat> does not return any output
  • Host needed to be reboot in order for ASE to restart ASE


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 16.0

Keywords

not, responded, veritas, hang, VFX , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Problem