Symptom
After creating a new Implementation in the new Custom Logic app, "Open Code Editor" button is not available/is greyed out.
Environment
SAP S/4HANA Cloud
Reproducing the Issue
- Go to the new Custom Logic app.
- Click on "Create" button.
- Choose the Extension Point (BAdI).
- Maintain the Implementation Attributes.
- Type an Implementation Description and ID.
- Click on "Review" button.
- After reviewing the implementation, proceed clicking on the "Create" button.
- On the upper right side of the page the "Open Code Editor" button will be greyed out.
Cause
Creating the Implementation means that all metadata has been written, but the actual underlying backend objects have not yet been generated. Therefore, it's only possible to open the Code Editor when the Implementation is published, when the backend objects are generated.
Resolution
Publish the Implementation to turn the "Open Code Editor" button available.
See Also
Keywords
Implementation, new, custom logic, open code editor, button, not available, greyed out, extension point, enhancement, badi , KBA , BC-SRV-APS-EXT-BL , Custom Business Logic , Problem