Symptom
Standalone Enqueue server 2.0 doesn't start.
Running "sapcontrol -nr <ASCSinstance nr> -function GetProcessList"
GetProcessList
OK
name, description, dispstatus, textstatus, starttime, elapsedtime, pid
msg_server.EXE, MessageServer, GREEN, Running, <starttime>, <elapsedtime>, <pid>
enq_server.EXE, Enqueue Server 2, GREY, Stopped,,,<pid nr>
In the dev_enq_server trace file there are the following messages:
[<timestamp>] [<nr>] sapstart.log found in work directory, process started by sapstartsrv
[<timestamp>] [<nr>] *** ERROR => Enqueue Server 2 is starting but Enqueue Server / Replication Server is configured (enq/enable=FALSE, rc=0) [EnqEnqueueSe 312]
[<timestamp>] [<nr>] *** WARNING => NiWakeupClose: parameter invalid (*ppServer == NULL) [nixxi.cpp 10014]
[<timestamp>] [<nr>] *** ERROR => IcmShutdown: NiWakeupClose failed: NIEINVAL (-8) [icxxman.c 1327]
Read more...
Environment
SAP Netweaver 7.51 and above
ABAP platform 1809 and above
Product
Keywords
enqueue server, ENSA 2 stopped, yellow , KBA , BC-CST-EQ , Enqueue , Problem