SAP Knowledge Base Article - Preview

3329029 - Install AMC Error in checking if Fault Manager is enabled -SRS

Symptom

  1. Install AMC from ASE 16 SP04 PL02
  2. to access the HADR Overview menu, it gets error "Error in checking if Fault Manager is enabled"
  3. AMC.log file

    org.apache.olingo.server.api.ODataApplicationException: Error in checking if Fault Manager is enabled.

     at com.sap.ase.nanna.hadrhost.HadrHostProcessor.readEntityCollection(HadrHostProcessor.java:71) ~[classes!/:1.0.08-RELEASE]
     ... 158 common frames omitted
    Caused by: org.springframework.jdbc.UncategorizedSQLException: StatementCallback; uncategorized SQLException for SQL [sp_configure 'FM']; SQL state [null]; error code [17411]; Configuration option is not unique.; nested exception is com.sybase.jdbc42.jdbc.SybSQLException: Configuration option is not unique.

  4. In ASE
     
    1> sp_configure 'FM'
    2> go
    Msg 17411, Level 16, State 1:
    Server 'syb_041', Procedure 'sp_configure', Line 410:
    Configuration option is not unique.
     Parameter Name          Default     Memory Used   Config Value   Run Value    Unit           Type
     ----------------------- ----------- ------------- -------------- ------------ -------------- -------
     FM Enabled                        0           0              1              1 not applicable dynamic
     SQL Perfmon Integration           1           0              1              1 switch         static


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0 with Always-on Option (HADR)

Product

SAP Replication Server all versions

Keywords

CR 827971, 827971, AMC, FM, Fault Manager , KBA , BC-SYB-REP , Sybase Replication Server (standalone) , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.