Symptom
- PD Web does not start up after the repository.xml file was customized to target another server/database.
- Multiple copies of web.xml were also customized.
- File portalserver16-stderr reports the following error:
SEVERE [localhost-startStop-1] org.apache.tomcat.util.descriptor.web.WebXmlParser.parseWebXml Parse error in application web.xml file at [file:/C:/Program%20Files/SAP/PowerDesigner%20Portal%2016/Tomcat/conf/web.xml]
org.xml.sax.SAXParseException; systemId: file:/C:/Program%20Files/SAP/PowerDesigner%20Portal%2016/Tomcat/conf/web.xml; lineNumber: 4735; columnNumber: 25; The element type "http-method" must be terminated by the matching end-tag "</http-method>".
Read more...
Environment
SAP PowerDesigner (PD) Web 16.7