SAP Knowledge Base Article - Preview

3338060 - SIGSEGV is caught by VEH_Optimize() with error 622 / signal 11 at bufallunkeep - SAP ASE

Symptom

  • The ASE error log reports a SIGSEGV is caught by VEH_Optimize
  • Which may have other messages
    • Before : error 622
      and/or
    • After : signal 11 in function bufallunkeep
  • Finally resulting in error 6103 and a phantom spid
  • The errorlog entries may vary, these may be seen


    SIGSEGV is caught by VEH_Optimize()
    Return VXACTION_CONTINUE from VEH_Optimize()

    Error: 622, Severity: 20, State: 1
    Opentable was passed a varno of 250. Object '' in database 'tempdb03' already has that session descriptor in use. This occurred while opening object id -49741826 in database id 12.
    ...
    lasterror = 622 preverror = 0 transtate = 1

    Current process infected with signal 11 (SIGSEGV)
    Address 0x0x000000000172b729 (bufallunkeep+0x4a9), siginfo (code, address) = (1, 0x0x0000000072616873)

    WARNING: Pss 0x0x00007f1f62a63c98 found with open sdes. pspid 759, psuid 1, pcurdb 10, system table entry 1, sdesp 0x0x00007f1f1d41b098, objid 24.
    Error: 6103, Severity: 17, State: 1
    Unable to do cleanup for the killed process; received Msg 8201