Symptom
- During upgrade using SUM, Enqueue Replicator 2 (ERS 2) does not start.
SUM screen shows below error:
Checks after phase MAIN_UPTRANS/STARTSAP_PUPG were negative!
Last error code set:
sapcontrol error at WaitforStarted: FAIL: process enq_replicator Enqueue
Replicator 2 not running
System start failed
- The command "sapcontrol -nr <instance_number> -function GetProcessList", shows output as below:
GetProcessList
OK
name, description, dispstatus, textstatus, starttime, elapsedtime, pid
disp+work, Dispatcher, GREEN, Running, 2023 08 21 19:54:08, 0:11:11, 13200
enq_replicator, Enqueue Replicator 2, GRAY, Stopped, , , 13201
igswd_mt, IGS Watchdog, GREEN, Running, 2023 08 21 19:54:08, 0:11:11, 13202
gwrd, Gateway, GREEN, Running, 2023 08 21 19:54:09, 0:11:10, 13208
icman, ICM, GREEN, Running, 2023 08 21 19:54:09, 0:11:10, 13209
- The trace file "dev_enq_replicator" under work directory shows below error:
[2023-08-21-19:29:31,210] [Thr 140334328964864] IcmInitEnqueueSecureCommunication: secure communication (SSL) is switched on
[2023-08-21-19:29:31,210] [Thr 140334328964864] ***LOG Q0I=> NiIBindSocket: bind [2023-08-21-19:29:31,210] (98: Address already in use) [2023-08-21-19:29:31,210]
[/bas/789_REL/src/base/ni/nixxi.cpp 3953]
[2023-08-21-19:29:31,210] [Thr 140334328964864] *** ERROR => NiIBindSocket: SiBind failed for hdl 17/sock 10
(SI_EPORT_INUSE/98; I4; ST; 0.0.0.0:3201) [nixxi.cpp 3953]
[2023-08-21-19:29:31,210] [Thr 140334328964864] *** ERROR => IcmBindService: NiBuf2Listen failed for host <host>:sapdp01 (rc=-4): NIESERV_USED [icxxserv.c 4283]
[2023-08-21-19:29:31,210] [Thr 140334328964864] *** WARNING => IcmAddService: Could not start service (rc=-22)
PORT=sapdp01,PROT=ENQUEUES,MAX_RECEIVE_TIMEOUT=10 [icxxserv.c 1454]
[2023-08-21-19:29:31,210] [Thr 140334328964864] ***LOG GO4=> IcmAddService, (sapdp01&ENQUEUES&) [icxxserv.c 1472]
[2023-08-21-19:29:31,210] [Thr 140334328964864] *** ERROR => FATAL: Service binding failed because port is in use! There might be another instance that uses the
same profile. Trigger shutdown! [icxxman.c 5535]
[2023-08-21-19:29:31,210] [Thr 140334871312320] IcmLoop: Shutdown request received
[2023-08-21-19:29:31,311] [Thr 140334871312320] IcmHandleShutdownEvent: all open connections will now be closed
[2023-08-21-19:29:31,311] [Thr 14033487131
Read more...
Environment
- Enqueue Replicator 2
- ABAP Platform
- SAP Netweaver
Product
Keywords
ERS, Enqueue Replicator 2,enq/replicatorport, Enqueue Replication,doesn't start, cannot start , KBA , BC-CST-STS , Startup Service , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.
SAP Knowledge Base Article - Preview