Symptom
The migration error log shows error: Unit of measure target value PC is not a valid ISO code (see long text) CNV_DMC_SIN477.
Environment
S/4Hana Cloud.
Reproducing the Issue
Create migration project for Asset Master Data.
Upload file and complete mapping.
Simulate.
Cause
You have set the unit of measurement as PC instead of the ISO code PCE.
Resolution
Change the mapping of the unit of measurement to PCE and simulate again.
See Also
Keywords
KBA , FI-AA-AA-A-2CL , Master Data (Public Cloud) , Problem
Product
SAP S/4HANA Cloud Public Edition all versions ; SAP S/4HANA Cloud all versions