SAP Knowledge Base Article - Preview

3420988 - Signal 11 at LeColumn::truncate - SAP ASE

Symptom

  • ASE errorlog reports an "infected with signal 11" error in the module LeColumn::truncate followed by a stack trace:
       
    Current process (0x1d000f) infected with signal 11 (SIGSEGV)
    Current Process is running on Engine 0
    Address 0x00000000800b0ba4 (int LeColumn::truncate(char,unsigned)+0x28), siginfo (code, address) = (1, 0x000000000000001d)
       
  • The stacktrace includes the following modules:
       
    LeColumn::truncate(char,unsigned)+0x28
    LeDataRow::_putVarLenValue(LeColumn*,int)+0x58
    LeDataRow::writeRowDOL_ins
    LeInsertOp::_LeOpNext(ExeCtxt&)+0x37c
    LeOperator::LeOpNext(ExeCtxt&)+0x6c
    LeEmitNoSndOp::_LeOpNext(ExeCtxt&)+0x158
    LeOperator::LeOpNext(ExeCtxt&)+0x6c
    LePlanNext+0xac
      
  • The terminated process (spid) is holding spinlock SSQLCACHE_SPIN, and ASE server crashes.
        
    Spinlocks held by  kpid 454362185
    Spinlock SSQLCACHE_SPIN[i] at address 0x00000001457dd500 owned by 454362185