Symptom
- After receiving a signal 11 at address bufdlink
- The ASE server terminates
- Due to holding spinlock on the default or on a user defined cache
- Typical errorlog entries include :
Current process (0x641f0075) infected with signal 11 (SIGSEGV)
Address 0x0x0000000001ddbd5f (bufdlink+0x7f), ....
Spinlocks held by kpid 1679753333
Spinlock default data cache at address ... -- other cache name may be seen
Followed by a stack trace with functions that can include:
bufdlink
bufpindirty
bufdirty
pg__getpgbuf
pg__allocate_completion
pg__allocate_near_target - Attached file KBA_Full_Sequence.txt shows a complete example of errorlog entries
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 16.0 SP03 & SP04
Product
SAP Adaptive Server Enterprise 16.0
Keywords
KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results