Symptom
When click mouse right button on an infocube, the following short dump occurs:
Category ABAP programming error
Runtime Errors SYNTAX_ERROR
ABAP Program /PBS/CL_CBW_PROTOCOL==========CP
Application Component Not assigned
Short Text
Syntax error in program "/PBS/CL_CBW_PROTOCOL==========CP ".
What happened?
Error in the ABAP application program.
The current ABAP program "/PBS/CL_NLSA_CONNECTION=======CP" had to be
terminated because it found a
statement that could not be executed.
In include "/PBS/CL_CBW_PROTOCOL==========CM001 ", in line 163 of program
"/PBS/CL_CBW_PROTOCOL==========CP ", the following syntax errors
have occurred:
Field "CBW_SX_VPSINFO-TSX_SELDR" cannot be a reference and cannot cont
ain references.
Field "CBW_SX_VPSINFO-TSX_SELDR" cannot be a reference and cannot contain references.
The infocube had NLS connection earlier and later NLS connection is decommissioned.
Read more...
Environment
- SAP_BW 750 SAP Business Warehouse
- PBSCBW H01_750 PBS CBW NLS
Product
Keywords
PBS, PBSCBW, H01_750, PBS CBW NLS, NLS Archiving, RSDANLCON , KBA , BW-WHM-DST-ARC , Archiving , Problem