Symptom
Display in the embedded PPDS system or the DSC system the product master.
The configuration relevance is shown as not relevant for configuration even if it should be, because:
- the configuration relevance is set to CDP or VC on the ePPDS or DSC system,
- one 300 class is assigned to the material master in S4core or ECC system.
- a configuration profile has been setup in S4core or ECC system
- the advanced planning flag is set (ePPDS) or the integration model for materials to your DSC system is active.
In the past in the SCM APO system the report /SAPAPO/CONFR_PROD_CONS was used in order to fix such inconsistent status on /SAPAPO/MATKEY-FLAGCLASS field.
This report can not be run on a S4 system any more as it can only run on SCM APO systems.
The below message is raised.
Image/data in this KBA is from SAP internal systems, sample data, or demo systems. Any resemblance to real data is purely coincidental.
Read more...
Environment
S4Hana with active ePPDS or an S4 DSC system.
Product
Keywords
/SAPAPO/MATKEY-FLAGCLASS, FLAGCLASS, MARA-FLAGCLASS, CDP, VC, configuration relevant, inconsistency, 400, 300, /SAPAPO/MARA_FLGCLS_CONS_CHECK, /SAPAPO/CONFR_PROD_CONS, /SAPAPO/MD400 , KBA , SCM-S4H-MD-PR , Product , SCM-APO-CA-CDP , Characteristics-dependent Planning , SCM-APO-INT-MD-CLC , Classes and Characteristics , SCM-APO-CA-VC , Variant Configuration , SCM-APO-INT-CON , Configuration , CA-CL , Classification , SCM-S4H-INT-MD , Master Data in DSC Edition , How To