Symptom
In HADR setup, replication server failed to start due to error below,
F. xxxx/05/18 12:50:03. FATAL ERROR #31124 GLOBAL RS(GLOBAL RS) - generic/sqt/sqtext.c(251)
Value for the configuration option 'sqt_max_read_delay' must be a positive integer between 2000 and 86400000 (both inclusive). Its current value is '250'. Check the RSSD table rs_config to make sure it contains a integer value between the valid range.
F. xxxx/05/18 12:50:03. FATAL ERROR #18028 GLOBAL RS(GLOBAL RS) - /servmain/servmain.c(2176)
Initialization failed. Server is shutting down.
Read more...
Environment
- SAP Adaptive Server Enterprise Always-on
- SAP Adaptive Server Enterprise 16.0
Product
Keywords
CR 829478, ERROR #31124, ERROR #18028, sqt_init_read_delay, sqt_max_read_delay , KBA , BC-SYB-REP , Sybase Replication Server (standalone) , BC-SYB-REP-SAP , Replication with SAP Suite / SAP BW , Problem