Symptom
A work process crashes with "signal 7" while performing operations on a VMC (Virtual Machine).
At the same time, the "/dev/shm" is full or almost full. This can be checked with the operating system level command "df -h".
The C-Stack might end with the following functions:
J [date and time]
J <VMC V3> <3> [7] Got Signal 7 at address 0x7f07f3c91000
M <VMC V3> si_code = 2
M <VMC V3> Sending process ID = -204926976
M <VMC V3> Real user ID of sending process = 32519
M <VMC V3> BUS_ADRERR: Non-existant physical address
M <VMC V3> 7f07f3c91000 (Memory location which caused fault)
M <VMC V3> C-STACK
dw.sapCRT_D52[S](LinStackBacktrace+0xa9)[0x5555e9dccbf8,0x7ccbf8]
dw.sapCRT_D52[S](LinStack+0x4d)[0x5555e9dcfbee,0x7cfbee]
dw.sapCRT_D52[S](CTrcStack2+0x4b)[0x5555e9dcb99a,0x7cb99a]
dw.sapCRT_D52[S](SigIGenAction+0x55d)[0x5555eb6502ca,0x20502ca]
libpthread.so.0[T][0x7f0a15619910,0x16910]
libjvm.so[S](CVMgenMarkCompactPromoteInto+0x117)[0x7f0a0bd6a067,0x16a067]
libjvm.so[S](CVMgenSemispaceGrayObject+0x230)[0x7f0a0bd6d020,0x16d020]
(...)
Read more...
Environment
- SAP NetWeaver ABAP based system with the VMC active
- SAP running on Linux.
Product
Keywords
CVMgenSemispaceGrayObject, CVMgenMarkCompactPromoteInto, "signal 7" , KBA , BC-VMC , Virtual Machine Container , BC-CST , Client/Server Technology , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.