Symptom
The execution of the DTP failed with the below error:
Delta Init cancelled: Subscription for DTP DTPI_FTL5YLGGFY2H8T4C74JVZJPFQ exists in Source system
Message No. RSBK267
Diagnosis
During the execution of the delta Initialization for DTPI_FTL5YLGGFY2H8T4C74JVZJPFQ, from the ODP Source System DR3CLNT110, a subscription for the DTP was found in the Source System (for the Operational Data Provider 0SVY_DATA_1).
System Response
The execution of the delta Initialization was cancelled.
Procedure
If the DTP was migrated in an Inplace or Remote Transfer and this is the first execution after the migration, you may experience a problem with the request transfer which should be addressed. In this case, please check note 2895337 and execute report RSB4H_CHECK_COMPLETE_REQ_TRNSF.
For all other cases, you can end the subscription in the Source System in Transaction ODQMON.
Read more...
Environment
SAP BW/4HANA 2023 all SP levels
Product
Keywords
Delta Init cancelled , Subscription , RSBK267 , ODP Source System , DTP , execution , RSB4H_CHECK_COMPLETE_REQ_TRNSF , KBA , BW4-DM-DTP , ABAP Orchestration of Data Transfer Process , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results