Symptom
- The system is unable to perform the 'Read PP Master data' function due to the active PMR.
- The error message /SPE/MAN 022: "Subsequent Reading BOM not allowed; PMR exists for order &1" is displayed.
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Create a production order
- Release the production order
- Run the WM material staging
- Attempt to use the 'Read PP Master Data' function
- Encounter error /SPE/MAN 022: "Subsequent Reading BOM not allowed; PMR exists for order &1"
Cause
Standard system behavior. When a PMR is created, the system status PMRC is activated for the component. This prevents the use of the "Read PP Master data" function.
Resolution
Encountering the error message /SPE/MAN022 is the expected behavior of the system.
Note that when a PMR is created, the system activates the PMRC status for the component, limiting some functions for the order.
The reason for this is to prevent any inconsistencies between EWM and the production/process order, It's a standard feature designed to maintain data integrity.
See Also
Keywords
/SPE/MAN022, PMR, EWM, Production Order, Read PP Master Data, SAP S/4HANA Cloud Public Edition, error, system behavior, PMRC status, data integrity, Process order, CO01, CO02, Change Production Order, Create Production Order, app. , KBA , PP-SFC-2CL , Production Orders (Public Cloud) , Problem