Symptom
In the Fiori app Migration Cockpit, when migrating measuring points using the "PM - Measuring Point" Migration Object, the "Transferred From" field is ignored, although the measuring points are migrated successfully.
Environment
SAP S/4HANA Cloud Public Edition.
Resolution
To correctly transfer the data, consider the following:
- Both fields "Date: Valid From" and "Time: Valid From" (column "Z" & Column "AA") are mandatory.
- The field "Time: Valid From" should not be 00:00.00, otherwise, the reading transfer will fail.
- The allowed values in the field "Mode of counter Reading Transfer" (column "AD") are either Blank or 1.
- "Blank" is - Counter reading transfer generates individual documents.
- "1" is - Counter reading transfer generates interval documents.
See Also
- PM - Measuring point | SAP Help Portal
Keywords
PM - Measuring Point, Transferred From, Transfer of, Date: Valid From, Time: Valid From, Mode of counter Reading Transfer, transfer supported , KBA , PM-EQM-SF-MPC-2CL , Measuring points and counters (Public Cloud) , Problem
Product
SAP S/4HANA Cloud Public Edition all versions