SAP Knowledge Base Article - Public

3552950 - Error "Exception condition "NO_ENTRY" triggered" when changing Master Inspection Characteristic in SAP S/4HANA Cloud Public Edition

Symptom

  • Migrate Master Inspection Characteristics (MIC) into the system using the staging table in Migrate Cockpit.
  • An error message "Exception condition "NO_ENTRY" triggered" is received when attempting to change these MICs in Change Master Inspection Characteristics app.

Environment

SAP S/4HANA Cloud Public Edition

Reproducing the Issue

  1. Migrate Master Inspection Characteristics in Migration Cockpit.
  2. Attempt to make changes to these characteristics in the "Change Master Inspection Characteristics" app.
  3. An error message "Exception condition "NO_ENTRY" triggered" is displayed and changes are not saved.

Cause

The "Cat. Type of Ass. Code Group or Sel. Set" field in the "Inspection Methods or Catalogs" sheet of the migration file is not maintained, which leads to a data inconsistency in the database.

Resolution

Maintain the "Cat. Type of Ass. Code Group or Sel. Set" field and migrate the data again.

See Also

Keywords

Master Inspection Characteristic, Change Master Inspection Characteristics app, Exception condition "NO_ENTRY" triggered, Migration Cockpit, data inconsistency, Cat. Type of Ass. Code Group or Sel. Set, QS23, Migrate Your Data, QPMZ , KBA , QM-PT-BD-2CL , Basic Data (Public Cloud) , Problem

Product

SAP S/4HANA Cloud Public Edition all versions