Symptom
When trying to change the project scope for change project, system shows:
"The project is active only in the test system. Open the test system to continue working on the project."
However, the change project is not editable in both production and test tenant.
Environment
SAP Business ByDesign
Reproducing the Issue
- Go to Business Configuration work center.
- Go to Implementation Projects view.
- Select the relevant change project.
- The change project cannot be edited and system shows:
"The project is active only in the test system. Open the test system to continue working on the project."
However, the change project is not editable in both production and test tenant.
Cause
The issue arises when a tenant refresh is performed post the 'Solution Profile Copy'. If the test tenant was refreshed from the production tenant, the created change project cannot be used. Instead, a new change project needs to be created, moved to the test tenant and worked with.
Resolution
Create a new change project, and move the new project to the test tenant and work with it.
See Also
Keywords
Edit Project Scope, Business Configuration, Implementation Project, Tenant Refresh, Change Project , KBA , AP-RC-BCT , Business Config. Tools (SAP Business ByDesign , Problem
SAP Knowledge Base Article - Public