Symptom
- ASE errorlog reports "Current process infected with signal 11 (SIGSEGV)" at address ptn__get_pdes.
- It can occurs when a client is inserting a row into a partitioned table and another client is running "alter table drop partition" command on the same table at the same time.
- The infected user task held the Pdes Chain Spinlock, so ASE automatically shuts down. Errorlog entries include:
Address 0x0x0000000001f133fd (ptn__get_pdes+0x5ad)
Current process (0xXXXXXXXX) infected with signal 11 (SIGSEGV)
../..
Spinlock Pdes Chain Spinlocks at address 0x0000000145808e80 owned by <kpid number>
- The error may be accompanied by a stacktrace referencing the functions:
ptn__get_pdes
ptn_get_pdes
ptn_pdes_set
open_partition
open__common_sdes_setup
sdes_hookup
Read more...
Environment
SAP Adaptive Server Enterprise (ASE) 16.0
Product
Keywords
830565, CR#830565, CR830565, signal 11 , infected, ptn__get_pdes, open__common_sdes_setup, access , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results