Symptom
When trying activate the Decision Table in Output Parameter Determination app in the Productive System some errors are displayed while Test System is working fine.
- DT_CHANNEL (Expression) : Columns must be adapted to change of result data object APOC_T_BRF_DT_CHANNEL Display Related Object (Technical Details) Display Help
- APOC_S_BRF_DT_CHANNEL (Data Object) : Component 'DISPATCH_TIME' of DDIC structure APOC_S_BRF_DT_CHANNEL is missing (Technical Details) Display Help
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Go to Output Parameter Determination app
- Set the Determination Rules
- Check the Decision Table
- See error messages
Cause
There is a difference in the Decision Table versions, which explains the different behavior between the systems.
Resolution
Ensure all steps outlined in the item 5.3 Transferring Settings from Output Parameter Determination in the Setting Up Output Management - 1LQ Set Up Guide.
See Also
- 3527419 - Message APOC_S_BRF_DT_CHANNEL in Output Parameter Determination app
- 2941522 - Output Management in SAP S/4HANA Cloud Public Edition - Guided Answer
- Setting Up Output Management - 1LQ Set Up Guide
Keywords
Activate, Decision Table, Output Parameter Determination, OPD Productive, Prod, System, errors, Test , KBA , CA-GTF-OC , SAP S/4HANA output management , Problem