SAP Knowledge Base Article - Preview

3603442 - Ownership Calculation Fails with ST22 dump STACK_STATE_NO_ROLL_MEMORY in BPC

Symptom

  • In BPC, calculating the ownership percentages using the group share method fails after 5 minutes.
  • In the network trace, a 500 internal error is returned.
  • In TCode ST22, the following dump is generated:
    • Category               Resource bottleneck
      Runtime Errors         STACK_STATE_NO_ROLL_MEMORY

    • Short Text
          No memory of length 2353575936 available for event stack.

    • What happened?
          Resource bottleneck

          Program "CL_UJP_OWNERSHIP_CAL==========CP" had to be terminated because a capacity limit has been reached.

    • Information on where terminated
          The termination occurred in ABAP program or include
           "CL_UJP_OWNERSHIP_CAL==========CP", in "CAL_MATRIX_OWN". The main program was "SAPMHTTP".

          In the source code, the termination point is in line 22 of include
           "CL_UJP_OWNERSHIP_CAL==========CM00T".


Read more...

Environment

  • SAP Business Planning and Consolidation, version for SAP BW/4HANA
  • SAP Business Planning and Consolidation, version for SAP NetWeaver

Product

SAP Business Planning and Consolidation, version for SAP BW/4HANA all versions ; SAP Business Planning and Consolidation, version for SAP NetWeaver all versions

Keywords

SAP Business Planning and Consolidation, SAP BW/4HANA, Ownership Manager, calculation error, internal server error, group share method, self-own data, POWN value, PCON, PCTRL, PGROUP, METHOD , KBA , EPM-BPC-NW-TDL-OWN , Ownership calculation , EPM-BPC-BW4-CON , BPC/4 - Consolidation, Controls, Journals , Problem