Symptom
- An error message "Change the inspection stock of material ABC in QM only" with Message number QA495 is encountered when attempting to move stock from unrestricted use to quality stock in plant, storage location and warehouse via the app Transfer stock in plant.
- The material seems correctly set up and inspection is active for the movement type.
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Navigate to the app Transfer Stock in Plant and select material and plant.
- Select batch.
- Select the bucket unrestricted-use stock in storage location and then click on the bucket for quality stock.
- In the pop-up, select the quantity to be transferred from unrestricted-use to quality stock and Post.
- The error message is displayed.
Cause
In public cloud it is not possible to integrate Quality management with third party WMS.
Resolution
Post the quantity back to quality stock using the Fiori application "Transfer Stock- In-Plant" (Fiori-ID F1061) or using any other application that allows goods movements of movement type 322.
Prerequisite for the process is the activation of an inspection type of inspection origin "Stock transfer" (08) in the quality view of the material master and that the stock posting was made to free or blocked stock. For details on how the process may look, Refer to scope item Logistics with Third-Party Warehouse Management (1ZQ).
See Also
Keywords
Quality Management, Third-Party-WMS, Public Cloud, Stock Transfer, Error QA495, Unrestricted Use, Quality Stock, Plant 1000, Storage Location 1040, Warehouse 100, Material V1710352, , KBA , QM-IM-2CL , Quality Inspection (Public Cloud) , QM-IM , Quality Inspection , Problem