Symptom
- Test connection fails when using AWS private link as SAP application server in datastore.
- Error message:
Test failed for the default configuration 'XXX' of datastore: 'XXX':
Cannot connect to SAP Applications datastore <> using host <AWS_private_link_addresss>, client <XXX>, user <XXX>, and system number <00: CRFC error: RFC_COMMUNICATION_FAILURE-
LOCATION SAP-Gateway on host SAP system real hostname / XXX
ERROR timeout during allocate
TIME Mon May 5 09:33:13 2025
RELEASE 777
COMPONENT SAP-Gateway
VERSION 2
RC 242
MODULE /bas/777_REL/src/krn/si/gw/gwr3cpic.c
LINE 2263
DETAIL no connect of TP sapdp00 from host AWS_private_link_addresss after 20 sec
COUNTER 4
[SAP Partner]>. Please make sure the SAP server is running and the login information is correct.
Read more...
Environment
- SAP Cloud Integration for data services
- SAP application datastore
Product
Keywords
CIDS, AWS, privatelink, timeout, allocate , KBA , LOD-HCI-DS , HANA Cloud Integration for Data Services , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.