Symptom
- Imported Dictionary entries do not appear in the suggested drop-down list, when updating the name for an element on a BPMN diagram.
- Only Dictionary entries created directly in Process Manager appear in the drop-down list.
Example Dictionary entries:
Dictionary entries not found when naming a model element:
Image/data in this KBA is from SAP internal systems, sample data, or
demo systems. Any resemblance to real data is purely coincidental.
Environment
Dictionary for SAP Signavio Process Manager.
Reproducing the Issue
- Import dictionary entries into the Process Manager workspace.
- Open a diagram and attempt to enter text for a model element.
- The imported dictionary entries do not appear in the suggested drop-down list.
Cause
The imported dictionary entries were incorrectly mapped during the import process.
Specifically, the keywords were entered into the "Description" field instead of the "Title" field.
Resolution
- Review the imported dictionary file to identify any incorrect mappings.
- Ensure that keywords are correctly placed in the "Title" field of the dictionary import file.
- Re-import the dictionary file with the corrected mappings.
- Verify that the imported entries now appear in the suggested drop-down list when entering text into an object on a diagram.
Keywords
imported dictionary entries, drop-down list, sap process manager, dictionary mapping, title field, description field, diagram text entry, dictionary import, sap dictionary troubleshooting. , KBA , BPI-SIG-PM-DIC , Dictionary for SAP Signavio Process Manager , Problem
SAP Knowledge Base Article - Public