Symptom
You exported a file using Export Master Data App for field MARA-BSTME, and you use the same file to start a mass maintenance process for Product to update BSTME field value. After the process is started, there is no field shown at the scope step.
Environment
SAP S/4 HANA Cloud Public Edition
Cause
With the standard setup of the Mass Maintenance Application, BSTME field is not supposed to be changed via Mass Maintenance - Product application.
Resolution
If you do need to use Mass Maintenance - Product App to change the field value in mass, please carry out the following workaround:
- Use Export Master Data App to export a file including an additional field which can be changed via the Mass Maintenance App, for example MSTAV.
- Prepare you change to field for BSTME in the new file and do not make any change to the other field MSTAV(To avoid unexpected change).
- Load the file again and field MSTAV is shown in the scope step. Though at scope field BSTME is not shown it will be considered as changed also.
- Proceed the process to the end and the value of field BSTME will be changed.
Keywords
BSTME, Mass Maintenance, Public Cloud , KBA , CA-MDG-CMP-MM , Material , CA-MDG-CMP , Consolidation & Mass Processing , Problem
SAP Knowledge Base Article - Public