SAP Knowledge Base Article - Preview

3649123 - Random SIGSEGV or 700 series errors reported in the error log - SAP ASE

Symptom

  • One or multiple signal 11 (SIGSEGV) are reported in the ASE error log
  • The stack patterns are not consistent
  • But the functions in the Address line and stacktrace indicate optimizer code is being executed.
  • Commonly seen stack modules have a variation of  Destructor or DestructObj:

    GcElement::DestructObj(OptPool*)
    TcElement::Destructor(OptPool*)
    TcElement::DestructObj(OptPool*)

  • Errors from the 700 series, such as 702 or 707, are reported at random times.
    • These may require reboot to clear


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0 & 16.1

Product

SAP Adaptive Server Enterprise 16.0.4 ; SAP Adaptive Server Enterprise 16.1

Keywords

SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace,  stack, registers, CR 831150, CR831150, 831150, CR#831150, _pGcDataType->getPool, getPool, _pGcDataType, 707, 702 , pexcproc , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Known Error