SAP Knowledge Base Article - Public

3662490 - Explode BOM API limitation for BOMs exceeding 9999 components - SAP S/4HANA Cloud Public Edition

Symptom

It is unable to explode all components when BOM has more than 9999 components.

Environment

SAP S/4HANA Cloud Public Edition 2508

Cause

The metadata for the fields 'path' and 'path_predecessor' in the Explode BOM API is defined with Precision="4" and Scale="0", which restricts values to a maximum of 9999.

Resolution

The issue will be fixed in CE2602.

See Also

Refer to: Explode BOM Documentation.

Refer to: Explode BOM API Overview.

Keywords

explode BOM API, BOM components limit, OData limitation, multilevel BOM explosion, 9999 components, Precision=4 Scale=0,path_predecessor , KBA , LO-MD-BOM-2CL , Bills of Material (Public Cloud) , Problem

Product

SAP S/4HANA Cloud Public Edition 2508