Symptom
- When changing a field value on position, error "Cannot read properties of undefined (reading '_writable')" is thrown
- Selecting 'OK' will allow you to bypass the error
- OnChange rules are configured on the affected fields
Environment
SAP SuccessFactors Employee Central
Reproducing the Issue
- Navigate to Position Org Chart
- Edit or create a new position
- Change some field values
- Notice error appears on screen
Resolution
-
SAP Engineering team are working on a code fix for this issue.
-
A patch fix is scheduled on 2511p4 (11-Nov-2025).
Workaround
- Disable any onChange rule on the affected field in Configure Object Definitions > Position > Affected Field > Details.
- OR Go to Manage Configuration UI and create a new UI for position object without any UI rules. Attach this UI to Position object default screen. onChange rules on the object can remain. Replicate again with the new UI and see the error no longer occurs.
See Also
- SAP SuccessFactors Product Release & Road Map Information
- SAP SuccessFactors Patches Knowledge Base
- KB Article 2171560 - How to be notified of new or updated SAP Notes or KBAs
Keywords
error, cannot read properties, undefined, writable, position error, SAP SuccessFactors, Employee Central, position org chart, manage positions, onChange rule, field value change, error message, troubleshooting, workaround, disable rule, SAP patches, SAP updates, KI2H2025, PTCH-48294
, KBA , LOD-SF-EC-POS-ORG , Position Org Chart UI & Manage Positions , Known Error