SAP Knowledge Base Article - Preview

3677840 - RepServer crash and stacktrace with signal 11 in _fstr_copy_cmd_val - SRS

Symptom

  • RepServer goes down due to a Signal 11 error with a stack trace:

         : Thread DSI EXEC(xxx(x) xxx.xxx) infected with signal 11.
         : Dumping memory trace.
         : ***************STACK TRACE***************
         : *****thread DSI EXEC(xxx(x) xxx.xxx)*******
         : (linux_dump_all_func_stack+0x35) []
         : (dbg_dump_stack_noarg+0x22) []
         : (dbg_dump_stack+0x10f) []
         : (exc__appDumpStack+0x11b) []
         : (exc_terminate+0x244) []
         : (linux_catch_signal+0x248) []
         : /lib64/libpthread.so.0(+0x12990) []
         : (pak_clone_cmdval+0x28) []
         : (_fstr_copy_cmd_val+0x70) []
         : (_fstr_substitute+0x441) []
         : () []
         : (fstr_map+0x2908) []
         : (_dsi_exec+0x1fa8) []
         : (_dsi_qm_exec_cmd+0x11f7) []
         : () []
         : (dsie_ProcessMsgFromSched+0x298) []
         : () []
         : (srv__start_function+0x1f3) []
         : /lib64/libpthread.so.0(+0x81ca) []
         : /lib64/libc.so.6(clone+0x43) []
         : *****End of stack trace.****


Read more...

Environment

SAP Replication Server (SRS) 16.0 SP04

Product

SAP Replication Server 16.0

Keywords

KBA , BC-SYB-REP , Sybase Replication Server (standalone) , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.