Symptom
The PMR is blocked due to the error message: "An error has occurred during conversion of the quantity."
This causes staging to be blocked for the production orders.
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Create and release a production order.
- Execute WM staging for the order.
- Observe that the PMR status is locked with an error message "An error has occurred during conversion of the quantity."
Cause
Missing Unit of Measure (UoM) for products with PMR-based quantity calculation in the Assign Bin to PSA app.
Resolution
- Access the Assign Bin to PSA app.
- Maintain the missing Unit of Measure (UoM) for the specific PMR-based quantity calculation products.
- Execute staging again for the affected production orders.
Keywords
PMR, quantity conversion error, staging failure, Assign Bin to PSA, Unit of Measure, locked PMR, production order, WM control cycle, staging blocked , KBA , SCM-EWM-PMR-2CL , Production Material Request (Public Cloud) , Problem
Product
SAP S/4HANA Cloud Public Edition all versions