Symptom
An integration flow using the OData V2 receiver adapter with 'Content Type' configured to 'Atom' in SAP Cloud Integration (CPI) fails with the following error during response processing:
om.sap.gateway.core.ip.component.odata.exception.ODataV2ResponseParsingException: Failed to parse response for created entity. Error message = Caused by:javax.xml.stream.XMLStreamException: Maximum attribute size limit (524288) exceeded in EntitySet
Read more...
Environment
- Cloud Integration
- SAP Integration Suite
Product
Keywords
OData V2 receiver adapter, XMLStreamException, maximum attribute size limit, SAP CPI, SAP Cloud Integration, integration flow error, response processing failure, XML attribute size exceeded, StAX XML parser limit, primary key size issue, Base64, encoded string, entity URL key value, XML attribute limit, JSON content type workaround, SAP Integration Suite, OData service design limitation , KBA , LOD-HCI-PI-CON-OD , OData Adapters , Problem
About this page
This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP for Me (Login required).Search for additional results
Visit SAP Support Portal's SAP Notes and KBA Search.