Symptom
Stuck queues for inspection lot with error messages:
- "data for storage type search is not defined (&1)" "/SCWM/L3 007".
- "Could not fully determine the destination data" "/SCWM/PUT_BIN_DET" "/SCWM/L4 054".
Environment
SAP S/4HANA Cloud Public Edition
Cause
Resolution
- Navigate to the Warehouse Monitor application → Tools → Application log.
- Set the object as "/SCWM/WME", subobject as "QINSP", and specify the relevant date and time.
- Locate the failed warehouse task (WT) log for putaway task creation.
- Review the WT log to identify the issue.
See Also
Refer to: SAP S/4HANA Cloud Documentation
Keywords
warehouse monitor, stuck queue, inspection lot, retry logic, data for storage type search, asynchronous execution, follow up action, retry attempts, quality management, public cloud, putaway control indicator, product master data, error message , KBA , SCM-EWM-QM-2CL , Quality Management (Public Cloud) , SCM-EWM-WOP-2CL , Warehouse Order Processing (Public Cloud) , Problem