SAP Knowledge Base Article - Public

3770526 - Inspection lot stuck in queue with error "no product putaway profile found" - SAP S/4HANA Cloud Public Edition

Symptom

  • Stuck queue entry for an inspection lot in the warehouse message queue
  • Error: "No product putaway profile found (putaway ctrl ind.:&1, storage typ...)"
  • Message ID /SCWM/WM_SEL 066

Environment

SAP S/4HANA Cloud Public Edition

Reproducing the Issue

  1. Perform usage decision for the inspection lot in Quality Management.
  2. Attempt to change stock from quality (Q) to unrestricted (F).
  3. Open Warehouse Monitor > Tools > Message Queue and observe the inspection lot entry stuck with error "No product putaway profile found ..."

Cause

Stock/handling unit related to the inspection lot remained at a resource (not in the intended storage type), preventing determination of a product putaway profile for the storage type.

Resolution

  1. Move all affected stock/handling units from the resource to the intended storage type/destination bin.
  2. Refer to: KBA 3650652 - How to move the stock out of resource - SAP S/4HANA Cloud Public Edition.
  3. Reprocess the stuck queue entry in Warehouse Monitor > Tools > Message Queue.
  4. If the queue still fails, verify customizing in “Define Product Putaway Profile” for the relevant putaway control indicator and storage type.

See Also

Keywords

inspection lot, message queue, no product putaway profile found, message 066, ewm, putaway control indicator, storage type, usage decision, qm, stock type Q to unrestricted, resource, handling unit, putaway profile, /scwm/, tmatpp , KBA , SCM-EWM-QM-2CL , Quality Management (Public Cloud) , SCM-EWM-WOP-2CL , Warehouse Order Processing (Public Cloud) , Problem

Product

SAP S/4HANA Cloud Public Edition all versions