Symptom
When selecting control key at operation level in Manage Inspection Plan app, you find some control keys are missing in drop down list.
Image/data in this KBA is from SAP internal systems, sample data, or demo systems. Any resemblance to real data is purely coincidental.
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Go to Manage Inspection Plan app.
- Select inspection plan and navigate to the operation level page.
- Click "Edit" button and check the control key.
- Observe that only a limited set of control keys is available for selection.
Cause
If "Insp. Char Required" is set in the control key, it specifies that inspection characteristics are to be maintained for operations in Quality Management (QM) and Production Planning (PP).
Therefore, only control keys with "Insp. Char Required" indicator enabled in configuration are available for selection at the operation level in Manage Inspection Plan app.
Resolution
Set "Insp. Char Required" indicator for control key in configuration activity 102001 - Define Control Key. Below is an example:
Keywords
Manage Inspection Plan, control key, inspection plan operations, Insp. Char Required, 102001, Define Control Key. , KBA , QM-IM-2CL , Quality Inspection (Public Cloud) , Problem