Symptom
When the same Master Inspection Characteristic (MIC) is assigned to multiple operations in an inspection plan, the characteristic does not appear on the quality certificate.
Environment
SAP S/4HANA Cloud Public Edition
Reproducing the Issue
- Create or use an inspection plan with multiple inspection characteristics, ensuring at least two characteristics reference the same Master Inspection Characteristic (MIC).
- Create an inspection lot and record results for all characteristics.
- Generate the standard inspection certificate or export the standard inspection lot XML.
- Observe that fewer characteristics are listed than defined in the plan.
Cause
Because multiple inspection plan characteristics reference the same Master Inspection Characteristic (MIC), the standard certificate/XML consolidates by MIC. As a result, characteristics sharing the same MIC are not printed in the XML.
Resolution
Make sure that the MIC is not assigned multiple times in the inspection plan. If this MIC is needed on several operations, consider creating a new MIC with same settings for each operation.
Keywords
quality inspection, inspection certificate, standard xml, missing characteristics, inspection lot, master inspection characteristic, MIC, duplicate MIC, certificate output, form template, QM_QUALITY_CERTIFICATE_FORM, s/4hana cloud, qm-im, quality management , KBA , QM-CA-CG-2CL , Quality Certificate Creation (Public Cloud) , QM-CA-CG , Quality Certificate Creation , Problem